Ultra Biocid

Ultra biocid l.jpg
1 / 31
0
0
1353 days ago, 440 views
PowerPoint PPT Presentation

Presentation Transcript

Slide 1

ULTRA BIOCID Technical Presentation

Slide 2

Purpose/Description Ultra Biocid is utilized for the bringing down of pH in compound treatment arrangements. Ultra Biocid is clear, 100% water dissolvable item. Ultra Biocid is focused to supplant conventional natural and inorganic acids.

Slide 3

Advantages Environmentally savvy: Low BOD/COD when contrasted with acidic and other natural acids. Safe to handle (not at all like mineral acids) No-Odor/No VOC's Strength of a solid corrosive without security concerns. Financially savvy versus add up to cost of utilizing different acids. No warming upon weakening (not at all like other solid acids).

Slide 4

Technical Specifications Ultra Biocid Normality 16.31 Density (g/ml) 1.53 pH <1.0 Freezing Point <- 10C

Slide 5

MSDS Highlights NFPA: Fire 0; Health 2; Reactivity 2 HMIS:Fire 0; Health 2; Reactivity 0 Toxicological Information: Eye Irritation: May Be Irritating Skin Irritation: Non Corrosive To Skin DOT Non-Regulated

Slide 6

Competitive items: fundamental acids Strength COD BOD Volatility Odor DOT Acetic Acid Glacial 1070000 760000 High Strong destructive/Flammable Acetic Acid 56 599200 425600 High solid destructive/Flammable Sulfuric Acid 98 0 Low Strong destructive Sulfamic Acid 50 28000 11200* Low none destructive Citric Acid 100 1248750 1062400 Low none Not Regulated Phosphoric Acid 100 0 Low none destructive Formic Acid 90 600000 240000* Low Strong destructive Oxalic Acid 100 337627 135000* Low none Not Regulated Ultra Biocid 100 23000 6100 none Not Regulated

Slide 7

Strength titration information versus different acids

Slide 8

Titrations

Slide 9

Titrations: Ultra Biocid(Adjusted quality to break even with 56% acidic corrosive)

Slide 10

Uses Some cases of Uses are: Pre-treatment shower pH alteration After-treatment shower pH change Waste stream pH conformity Bleach balance (souring) Metals Manufacturing Substitution for most Industrial mineral Acids Many more......

Slide 11

Environmental Ultra Biocid does not contain any chemicals as of now on the EPA's Extremely Hazardous Substance List or the Toxic Chemicals List, Sara Title III segment 302 or 313. It is EPA Section 304,311 and 312 managed in light of the fact that the pH is under 2.0.

Slide 12

Storage Ultra Biocid can be put away in 316 stainless steel, high thickness polyethylene or polypropylene compartments. UCI International Inc. has been utilizing a similar tanker (316 stainless) and pipelines for more than 7 years with Ultra Biocid and have had NO erosion issues.

Slide 13

Shipping Ultra Biocid is NOT managed by any of the accompanying Transportation offices: D.O.T. I.A.T.A. I.M.D.G. T.D.G For Air Transportation: D.O.T. Controls as ORM-B, NOS; NA1760

Slide 14

Conclusion Ultra Biocid 's pH alteration science can give a financially savvy other option to customary natural and mineral acids. While enhancing general wellbeing of the work environment, representatives and the earth.

Slide 15

ULTRA BIOCID-GENERAL CHARACTERISTICS SAFETY 1-VERY SAFE PRODUCT WHICH HAS NO ODOR, FUMES OR VAPOR PRESSURE 2-NO AFFINITY FOR HUMAN FLESH-WILL CAUSE NO BURNS OR BLISTERING-SEE DERMAL IRRITATION TESTS 3-EASY STORAGE; REQUIRES NO SPECIAL HANDLING OR CONTAINERS 4-NO FUMES MEANS NO CORROSION WHEN USED AT AMBIENT TEMPERATURES-SEE METAL CORROSION TESTS 5-NO MUTAGENICITY-SEE AMES ASSAY 6-NON TOXIC-LD-50 1121 mg/kg(RATS, ORAL) 7-NO HEAT LIBERATION UPON DILUTION

Slide 16

ULTRA BIOCID-GENERAL CHARACTERISTICS ENVIRONMENTAL 1-VERY LOW BOD/COD-MUCH LOWER THAN ACETIC AND CITRIC ACID 2-CONTAINS NO PHOSPHATES, CHLORIDES, ETC. 3-NOT KNOWN TO INCREASE WASTEWATER DISCHARGE LIMITS

Slide 17

ULTRA BIOCID-GENERAL CHARACTERISTICS ECONOMY 1-COMPETITIVE AGAINST MOST COMMONLY USED ACIDS 2-NEW US PATENTED TECHNOLOGY

Slide 18

NEUTRALIZATION OF CAUSTIC TREATED DENIM FABRIC SUBJECTED TO HIGH AMOUNTS OF CAUSTIC (NaOH half) WILL EXHIBIT FACE AND BATH pH's OF APPROXIMATELY 12.0 – 13.0 AS THESE GOODS ARE PROCESSED ON A CONTINUOUS WASH RANGE, A WIDE ARRAY OF pH RANGES MAY BE ADJUSTED USING ULTRA BIOCID

Slide 19

NEUTRALIZATION OF CAUSTIC TREATED DENIM PROCEDURE INTO THE FIRST OR SECOND WASH BOX A CONTINUOUS FEED OF ULTRA BIOCID IS INTRODUCED PLUS WASH WATER WHICH IS ALLOWED TO OVERFLOW. THE AMOUNT OF ULTRA BIOCID ADDED IS DETERMINED BY THE DESIRED FABRIC FINISH pH REQUIRED, THE MACHINE SPEED AND TO A LESSER DEGREE THE FABRIC WEIGHT. AS AN EXAMPLE, MOST DENIM WILL REQUIRE A ULTRA BIOCID ADJUSTED BATH pH OF APPROXIMATELY 1.5 – 2.0 @ A MACHINE SPEED OF 60 – 80 YPM

Slide 20

NEUTRALIZATION OF CAUSTIC TREATED DENIM PROCEDURE CONTINUED UNDER THESE OPERATING CONDITIONS, EXIT FABRIC FACE pH'S WILL EQUAL APPROXIMATELY 8.0 – 9.5 IN-PLANT ADJUSTMENTS OF THE ULTRA BIOCID FLOW RATE WILL ALLOW THE WASHER OPERATOR TO ACHIEVE ANY pH RANGE DESIRED BECAUSE ULTRA BIOCID HAS NO VAPOR PRESSURE, EXTREMELY STEADY AND LEVEL pH RANGES ARE POSSIBLE WHEN COMPARED TO OTHER ACID SOURCES

Slide 21

NEUTRALIZATION OF CAUSTIC TREATED DENIM MAINTENANCE IT IS STRONGLY RECOMMENDED THAT ALL PROCESS EQUIPMENT BE CLEANED AND RINSED FREE OF ANY RESIDUAL ULTRA BIOCID AFTER PROCESS IS COMPLETE SO AS NOT TO ALLOW DRIED SALTS TO REMAIN ON EQUIPMENT. In the event that DRIED SALTS ARE EXPOSED TO HIGH TEMPERATURES OVER A SUSTAINED PERIOD OF TIME, THE POSSIBILITY OF CORROSION MAY OCCUR. Basic CLEANING WITH WATER WILL ELIMINATE THIS POSSIBLE CONDITION SINCE THESE ACID SALTS WILL READILY DISSOLVE.

Slide 22

LABORATORY TESTING

Slide 23

BIOCID TESTING DUE TO ULTRA BIOCID'S UNIQUE CHEMISTRY, SOME MINOR DIFFERENCES MAY BE NOTED DURING LAB EVALUATIONS AS COMPARED TO ACETIC ACID, FOR EXAMPLE, ULTRA BIOCID'S BUFFER POINT IS APPROXIMATELY 2.0 AND ACETIC ACID IS APPROXIMATELY 3.8 BECAUSE OF THE BUFFER DIFFERENCES, CUSTOMERS USUALLY ATTEMPT TO ADJUST ULTRA BIOCID BY ADDITIONAL STRENGTH CUTS WHICH WILL LEAD TO INCONSISTENT pH READINGS AND ERRONOUS RESULTS

Slide 24

BIOCID TESTING-CONTINUED WE STRONGLY SUGGEST THAT THE AMOUNTS OF ULTRA BIOCID RECOMMENDED BE FOLLOWED IN ALL CASES AS IT WILL SAVE VALUABLE LAB TIME AND MINIMIZE MISTAKES BIOCID'S LOWER BUFFER POINT WILL REACH EQUILIBRIUM VERY QUICKLY AS IT DISASSOCIATES WHICH WILL EQUATE THE ACID BEING TESTED SEE CHART AND GRAPHS FOR ADDITIONAL ASSISTANCE ULTRA BIOCID IS EASILY BLENDED WITH WATER TO THE REQUIRED pH STRENGTHS WITH INCREDIBLE SAFETY AND EASE OF HANDLING

Slide 25

BIOCID DYEBATH pH ADJUSTMENTS

Slide 26

BIOCID DYEBATH pH ADJUSTMENTS BIOCID WILL READILY AND SAFELY ADJUST DYEBATH pH RANGES BIOCID MAY BE USED ON ANY DYEING EQUIPMENT AND FOR ANY FIBER AND FIBER BLENDS EXAMPLES OF DYE EQUIPMENT INCLUDE JETS, PACKAGE MACHINES, BECKS, BEAMS, HOSIERY MACHINES OF ALL TYPES, CONTINUOUS DYE RANGES, ETC. BIOCID EXHIBITS NO UNUSUAL SPECTRA SHIFTS WHEN USED AS RECOMMENDED – NO DIFFERENCES IN DYE YIELDS NOTED. SEE CHARTS FOR STRENGTH COMPARISONS OF VARIOUS ACIDS

Slide 27

BIOCID STRENGTH VS VARIOUS ACIDS

Slide 28

10 ml ACETIC ACID (GLACIAL)- - 10 ml ACETIC ACID (84%)- - 10 ml ACETIC ACID (70%)- - 10 ml ACETIC ACID (56%)- - 10 ml ACETIC ACID (20%)- - 10 ml FORMIC ACID - - 10 ml PHOSPHORIC ACID - 10 ml SULFAMIC ACID (15%)- - 10 ml OXALIC ACID - - 10 ml CITRIC (half)- - - 10 ml SULFURIC ACID(70%)- - 10 ml BIOCID 7 ml BIOCID 5 ml BIOCID 4 ml BIOCID 2 ml BIOCID 10 ml BIOCID 10 ml BIOCID 3 ml BIOCID 11 ml BIOCID 5 ml BIOCID 11 ml BIOCID STRENGTH VS VARIOUS ACIDS TABLE #1

Slide 29

BIOCID STRENGTH VS VARIOUS ACIDS ALL STRENGTH COMPARISONS ARE TO BE USED AS GENERAL GUIDES ONLY LABORATORY TESTING IS SUGGESTED TO VERIFY COMPARISONS

Slide 30

BIOCID'S USE IN WASTEWATER

Slide 31

BIOCID'S USE IN WASTEWATER ULTRA BIOCID IS WIDELY USED TO TREAT PLANT AND MUNICIPAL WASTEWATER WHEN pH ADJUSTMENTS ARE REQUIRED BECAUSE ULTRA BIOCID HAS VERY LOW BOD/COD REQUIREMENTS, AND CONTAINS NO PHOSPHATES, MANY CUSTOMERS USE BIOCID TO ASSIST IN THEIR WASTEWATER TREATMENT BIOCID WILL REPLACE SULFURIC ACID AND ALSO CARBON DIOXIDE GAS BIOCID IS NORMALLY ADDED AT THE LAST WASTEWATER DISCHARGE EXIT TO CONTROL pH AND BOD/COD

SPONSORS