Power Module Setup

0
0
1564 days ago, 551 views
PowerPoint PPT Presentation

Presentation Transcript

Slide 1

Control Module – Setup Before utilizing the Power Module (PM) to control the HeartMate II or XVE LVAS and discretionary Display Module or System Monitor, set up the PM for use by associating its inside battery and connecting the power rope and patient link. PMs are delivered to focuses with their inside batteries detached. Endless supply of the PM, the inside's biomedical specialist or other prepared faculty must open the PM and associate its interior battery preceding utilizing the gadget.

Slide 2

Power Module – Connecting the PM Power Cord and PM Patient Cable Follow these means to interface the PM control string and patient link: Place the PM on a level strong surface . Acquire the dim AC control string and place the female end of the connector into the PM's energy section module. Once the rope is embedded into the power passage module, lift the power rope maintenance cut into the bolted position; embed the two closures of the clasp into the openings. Connecting with the clasp will guarantee that the AC control line does not turn out coincidentally. 2 3

Slide 3

Power Module – Connecting the PM Power Cord and PM Patient Cable Plug the PM's dim power rope into a legitimately test and grounded (3-prong) AC electrical outlet that has been committed for PM utilize. Make certain that the outlet is not controlled by a divider switch. In the wake of connecting the power string to the AC mains electrical outlet, watch the front board of the PM for brightening of the green "power on" light. In the event that the light does not go ahead in the wake of checking the capacity of the AC outlet, don't utilize the PM and contact Thoratec for a substitution, if necessary. Acquire the PM quiet link from item bundling. 5 6 Power On ("I") Light

Slide 4

Power Module – Connecting the PM Power Cord and PM Patient Cable Line up the red specks between the patient link and the attachment with the "heart" image situated in favor of the PM and after that embed the patient link into the attachment. In the wake of embeddings the connector cozily into the attachment, watch that the association is tight. Pull delicately on the strain help segment of the connector. Try not to pull on the link. Start an individual test on the Power Module. After the PM's inward battery has been charged, the PM is connected to, the patient link is associated with the attachment, and an individual test has been started, the PM is prepared for utilize. 7 8 Grasp here to check if association is tight

Slide 5

Power Module – Performing a Self Test Perform a PM Self Test before utilizing the PM interestingly and at any rate once every day to guarantee that the PM is working legitimately: Press and hold the PM's Alarm Silence Button for five seconds. Listen for… the discontinuous sound tone (3 beeps) Look for… the front of the PM to check whether every one of the lights enter arrangement (i.e., each one in turn, not at the same time). Disappointment of the PM Self Test is demonstrated by: No solid Anything other than a persistent tone, (for example, beeping or broken tone) All the lights go ahead without a moment's delay All the lights stay off One of the lights does not go ahead If any of the conditions recorded above happen, call Thoratec's Technical Services Department. Generally the PM has breezed through the Self Test and is prepared for utilize. Effective finish of a Self Test demonstrates that the PM is working legitimately and prepared for utilize.

Slide 6

Power Module – Alarms

Slide 7

Power Module – Alarms Cont.

Slide 8

Power Module – Backup Power When new, the inward reinforcement battery gives roughly 30 minutes of reinforcement energy to the HM II LVAS (45 for XVE) in case of AC power intrusion or disappointment. The inward reinforcement battery stays charged the length of the PM stays associated with AC power or vehicle DC control. In the event that the PM is disengaged from outside power, the inward battery will work the LVAS and the PM will caution until the battery is exhausted.

Slide 9

Power Module – Silence Alarm Button Pressing the Silence Alarm Button hushes a sound caution. On the off chance that another caution condition emerges amid a quiet period, another alert will sound. After the quiet time frame closes, the sound caution will continue, unless the alert condition has been determined. Squeezing the Alarm Silence Button just hushes the alert; it doesn't settle the caution condition.

Slide 10

Power Module – Connecting the System Monitor Follow these means to associate the System Monitor to the Power Module (PM): Plug the System Monitor link into the attachment situated in favor of the PM. Plug the flip side of the link into the System Monitor. Guarantee that the PM is connected to a legitimate AC outlet. Guarantee that the Patient link is connected to the PM and System Controller. Turn on the System Monitor by squeezing the on/off switch at the back of the System Monitor to the on position. A green light on the front of the System Monitor ought to enlighten once power is setting off to the gadget. 2 & 5 1 On/Off Switch

Slide 11

Power Module – Connecting the System Monitor Observe the System Monitor screen. When power is turned on, the HeartMate logo screen ought to show up. On the off chance that the System Monitor stays dark, check the accompanying: The System Monitor link is safely associated with the System Monitor and completely embedded into the attachment situated in favor of the PM. The System Monitor control switch is in the "on" position. The PM is getting satisfactory power from a working AC outlet (green "power on" light is lit up). 6

Slide 12

Power Module – Connecting the System Monitor If "NOT RECEIVING DATA" is blazing on the System Monitor screen, the System Monitor can't perceive or "see" the System Controller. In the event that this happens, check the accompanying: The "Patient" link is safely embedded into the attachment with the "heart" image situated in favor of the PM. The Display Module/System Monitor link is safely associated with the System Monitor and completely embedded into the attachment situated in favor of the PM. The System Controller control lead connectors are appropriately associated with the PM control lead connectors. On the off chance that the System Monitor still does not work, call Thoratec for help.

Slide 13

Power Module – Connecting the Display Module Follow these means to associate the Display Module to the Power Module (PM): Ensure that the patient link is joined to the PM and System Controller. Guarantee that the PM is connected to an appropriate AC outlet. Get the Display Module link connector. Embed the male end of the connector into the female end of the information link container. Solidly press together the connectors to guarantee a tight association. Fix the two thumb screws on the connector to secure the association. Adjust the depressions between the connector and the attachment found in favor of the PM; embed the connector into the attachment. 3 4 5

Slide 14

Power Module – Traveling via Car As a comfort, the PM can be connected to a car DC electrical plug (e.g., cigarette lighter attachment) to control the LVAS while going via auto. To interface with DC control when going via auto, take after these means: Obtain a Thoratec-gave vehicle DC control link. Change to battery-fueled operation, if in fastened mode. Before separating the PM from power, check that the reinforcement battery is charged (i.e., the green inward reinforcement battery light is on). Bring the PM , PM persistent link, DC control link, a reinforcement set of completely charged batteries, and good battery clasps to the auto. Enter the vehicle. With the vehicle appropriately stopped, begin the engine. Ensure the auto engine is running. Associate the DC control link to the PM, at the female connector marked 1 7

Slide 15

Power Module – Traveling via Car Plug the PM persistent link into the "heart" attachment found in favor of the PM. In the wake of embeddings the connector cozily into the attachment, watch that the association is tight. Pull delicately on the strain alleviation part of the connector. Plug the auto end of the car DC control link into the DC control attachment in the vehicle. On the off chance that appropriately associated, the green power on light on the front of the PM will enlighten. Take after the technique for going from untethered to fastened operation. Keep the batteries and clasps adjacent in a perfect, dry area while not being used. Put the PM on a low level area and turn it with the goal that you can see its lights on the front board. 8 & 9 Grasp here to check if association is tight

Slide 16

Power Module – Inspection, Cleaning & Maintenance Once every day , play out a PM System Self Test. At whatever time the patient changes from batteries to PM-fueled operation (e.g., before going to bed around evening time), investigate the connector pins and attachments for harm, soil, oil, and so on. At any rate once per week , investigate the power rope used to associate the PM to an electrical outlet. Ensure the string is not crimped, split, cut broke, or frayed. Try not to utilize the string on the off chance that it hints at harm. Acquire a substitution, if necessary. In any event once every week, examine the PM understanding link used to interface the patient to the PM. Ensure the rope is not wrinkled, split, cut broke, or frayed. Try not to utilize the link on the off chance that it hints at harm. Acquire a substitution, if necessary. Once per month , review the pins and attachments of the PM link/lead connectors and DC input link for harm, soil, oil, and so on. Once per year, convey the HeartMate PM to an approved administration expert for an exhaustive investigation and cleaning that incorporates: useful trial of the gadget, supplanting inside reinforcement battery, supplanting the patient link and examining the power line.