Panasonic Advanced Ventilation Fans

Slide 2

Panasonic Advanced Ventilation Fans 40/20 CFM Spot Energy Recovery Ventilator Dual speed settings for 40/20 or 20/10 CFM - 0.8 Sone at 40 CFM/<0.3 Sone at 20 CFM FV-04VE1

Slide 3

Panasonic Advanced Ventilation Fans Operation 2-speed settings

Slide 4

Panasonic Advanced Ventilation Fans Features: Balanced Ventilation Exhaust & Supply Air Exchange Core Temper Air

Slide 5

Panasonic Advanced Ventilation Fans 58℉ 46℉ 32℉ 72℉

Slide 6

Panasonic Advanced Ventilation Fans

Slide 7

Panasonic Advanced Ventilation Fans Features: Spot ERV – Home Office/Game Room/Family Rooms/Bedrooms Whole-House ERV – Housing Authority Properties/Hotels/Studio Apts.

Slide 8

Panasonic Advanced Ventilation Fans Features: Motor Technology – completely encased AC condenser engine, one engine works two fan wheels Filters – for supply and fumes side to keep trade center clean Grille – contemporary plan No deplete important!

Slide 9

Panasonic Advanced Ventilation Fans Operation Switches On = Hi or Lo dash Off = shutdown On Off 40/20 CFM (processing plant preset) 20/10 CFM Hi Lo Switch not provided Switch marks are accommodated discretionary utilize

Slide 10

White A.C. 120V Black Ground Orange Yellow On/Off Blue Hi/Low

Slide 11

Panasonic Advanced Ventilation Fans Operation Frost Prevention Mode Above 32 degree F Both fumes and supply completely work From 32 – 20 degree F Supply closes 30 minutes then opens 1 hour Below 20 degree F Supply closes 1 hour then opens 10 minutes

Slide 12

Panasonic Advanced Ventilation Fans 37 ° F (3 ℃ ) 32 ° F (0 ℃ ) temperature 19 ° F (-7 ℃ ) Exhaust just - 13 ° F (-25 ℃ ) 30m 10m 30m 1h Damper Open Damper Close 40 cfm 20 cfm Defrost Operation ( 40 CFM )

Slide 13

Panasonic Advanced Ventilation Fans

Slide 14

Panasonic Advanced Ventilation Fans Installation Mounting – Unit 14 inches wide. Fits between 16" on focus joist Wiring – 120/60 V/Hz 2 switches for on/off and high/low Duct – 4" protected pipe (suggested) for fumes and supply. Terminations (outside hoods) – isolate by 3 feet or point 45 degrees inverse bearings

Slide 15

Panasonic Advanced Ventilation Fans Installation 3 ft min.

Slide 16

Panasonic Advanced Ventilation Fans Maintenance: Grille – light dish cleanser Filters – vacuum with delicate brush connection Exchange Core - vacuum with delicate brush connection

Slide 17

Panasonic Advanced Ventilation Fans Example 1: Two rooms 1600 square feet Master room (7.5 CFM x 2) = 15 CFM Second room = 7.5 CFM 1600 sq ft x .01 = 16 CFM Total 38.5 CFM Use WhisperComfort set at 40 CFM Sizing – Based on ASHRAE 62.2 Example 2: Four rooms 2200 square feet Master room (7.5 CFM x 2) = 15 CFM Other 3 rooms 7.5 each = 22.5 CFM 2200 sq ft x .01 = 22 CFM Total 59.5 CFM Use 2 WhisperComfort Or 1 WhisperComfort and 1 WhisperGreen

Slide 18

Panasonic Advanced Ventilation Fans Ventilation Capacity Requirements (CSA-F326) 10CFM Single Bed room Living room Family room 20CFM Master Bed room Large Basement room ASHRAE62.2 2004 ASHRAE62 2001 (0.35 ACH) 1 Bed room 2 Bed room 3 Bed room 20CFM 500Ft 2 N/A N/A 429 Ft 2 40CFM 2500 Ft 2 1750 Ft 2 1000 Ft 2 857 Ft 2 Spot Ventilation Need to be picked 10/20 CFM mode when it's introduced. Entire House Ventilation (IAQ) Need to be picked 20/40 CFM mode when it's introduced.